Automatic Genset Controllers with Transfer Switching


automatic genset controller with transfer switching   Features:
CanBus J1939 ECU communication
Parameter configuration via USB port of your notebook
Authorised access, secure communication
Translate LCD text to your language
Log last 50 events & alarm information with measured values with real time stamp
Statistics records
Generator phase sequence control
Remote Start/Stop, Speed and Idle mode control via J1939
Power factor measurement for 3 phases
4 resistive sender inputs for Level, Temperature, Oil Pressure and Spare
Selectable resistive sender types; Pt-100, VDO, US, GM, Ford, Datcon, etc...
Speed sensing from alternator voltage or magnetic pickup
3 phase load current and earth current measurement
Configurable 10 inputs and 4 outputs
ECU power, ECU stop, Stop or Fuel Solenoid selection
Programmable weekly working permit calendar
Maintenance warning, Red (Shutdown) and Yellow (Warning) alarm lights
Navigation and Shortcut buttons for easy use
Exercise at programmed time intervals
Load Test selection
Automatic transfer switching control and engine control
Compatible to Diesel or Gas generators
Auto, Manual and Test Modes
Active, Reactive and Apparent power measurement
Adjustable Start, Load and Stop timers
SPN, FMI and OC values reading from engines via J1939
     
Datasheet on Genset Controllers with Transfer Switching ► Automatic Genset Controllers with Transfer Switching

 

Pre-Alarm
Engine temperature
Oil Pressure
Fuel level
Over/Under voltage
Over/Under frequency
Over/Under speed
 
Controls
Fuel and Stop solenoid
ECU power and stop
Starter motor
Automatic generator start
Load transfer to mains
Preheat
External alarm horn
Engine cooling
Idle mode
 
Warning & Electrical Trip
Earth fault
Over current
Short circuit
 
Alarm
Mains breaker not opened
Mains breaker not closed
Generator breaker not opened
Generator breaker not closed
Fail Monitoring
Emergency stop
Multiple engage fail
Failed to start
Low oil pressure
High temperature
Speed failure
Voltage
Charging fail
Shutdown
Warning
 
Error
Over/Under speed
Speed loss
Earth fault
Fuel level
Battery low
Battery high
Maintenance
Over current
Short circuit
Engine stop
CanBus
Charge alternator
 
 

 

 